Home » Accessories » Power Equipment » Pdus » PDU3VN10L1530

Tripp Lite 3-Phase Monitored PDU3VN10L1530 36-Outlets 8.6kW PDU - 6 X IEC 60320... 

2 in stock (as of 12/04/2016 11:30 AM)

Shipping Estimate:
Qualifies for FREE Shipping!
Within the Continental USA
Tripp Lite 3-Phase Monitored PDU3VN10L1530 36-Outlets 8.6kW PDU - 6 x IEC 60320 C19, 30 x IEC 60320 C13 - 8.6kW - Zero U Vertical Rackmount
Zoom panel loading...


Additional Images:   Medium | Original | Front | 900 | 1100 | FrontMaximum
Added to our catalog within last 30 days
Model: PDU3VN10L1530
View other products from Tripp Lite

$831.00
Estimated Shipping: FREE

Description

Pdu3vn10l1530 monitored 3 phase 208v zero u vertical rack pdu supports 8.6kw total output capacity. Includes 10 ft. / 3m input cord with nema l15-30p 30a (3p+e) 208v 3 phase input plug and 36 208v outlets arranged in 3 individually breakered single phase output load banks. Each output loading bank contains 12 outlets (10 c13 and 2 c19). Visual meter with scroll button and poweralert remote monitoring interface enables real-time current monitoring for each output phase. Supports 0u vertical rackmount installation with included mounting accessories. Toolless button-mount installation supported in compatible racks. Included cord retention brackets keep vital network equipment plugged in and continuously powered. Tripp lite 3 phase monitored pdu / power distribution unit offers real-time remote monitoring of voltage frequency and load levels via secure web snmp or telnet interface and whole rack ac power distribution. Poweralert interface supports custom notification of user-specified remote conditions via email secure web snmp telnet or ssh interface. Pdu output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical it mains breakers trip. Supports in-rack environmental and security monitoring for advanced configurations with optional envirosense temperature / humidity probe and rack access notification for up to 4 door sensors (srswitch) or other user-supplied contact-closure sensors. Lighted display with scroll-button offers power consumption in amps for all 3 loading banks ip-address self-identification and 180 degree display rotation for overhead or raised floor power feeds. Supports real-time monitoring of all reported functions with support for user-specified alarm and notification thresholds. Fully compatible with poweralert network management system / nms software available via free download from www.Tripplite.Com key features 8.6kw 3 phase 208v monitored power distribution unit (pdu) with built-in web/network interface attached nema l15-30p 30a (3p+e) 208v 3 phase input plug with 10 ft. / 3m cord 0u 70 inch / 178cm vertical form factor supports installation in 2 or 4 post equipment racks 36 total 208v outlets (30 c13 6 c19) arranged in three individually breakered single phase output load banks lighted display with scroll-button offers power consumption in amps for all 3 loading banks ip-address self-identification and 180 degree display rotation for overhead or raised floor power feeds. Built-in snmp/ethernet interface reports voltage frequency and pdu loading per-phase via network or secure web browser interface supports logging of all power events with user specified alarm and notification thresholds for load levels and site voltage conditions supports in-rack environmental and security monitoring for advanced configurations with optional envirosense temperature / humidity probe and rack access notification for up to 4 door sensors (srswitch) or other user-supplied contact-closure sensors. Dhcp/manual configuration support provides the ability to have network settings automatically assigned to the card or manually assigned a static ip addresses 10/100 mbps auto-sensing allows optimal communication compatibility with your current 10/100 base-t network real-time clock backup maintains the time of day and date even if the pdu is shut down and unpowered tiered access privileges allow an administrator and a guest to log into the web browser for monitoring all pdus alert notifications via email or snmp traps give users the added advantage of having an immediate event notification firmware upgrade ability supports future product enhancements. Protocols supported include http https poweralert network management system smtp snmpv1 snmpv2 telnet ssh ftp dhcp bootp ntp fully compatible with poweralert network management system / nms software available via free download from www.Tripplite.Com included cord retention brackets keep vital network equipment plugged in and continuously powered toolless mounting supported in button-mount compatible racks plus nut-and-bolt mounting brackets for other mounting applications typical applications ideal for 3 phase network configurations in datacenters and heavily configured equipment racks package includes monitored rackmount pdu with pre-installed mounting buttons cord retention brackets rack mounting brackets owner's manual

Package Contents:
  • Monitored PDU3VN10L1530 36-Outlets 8.6kW PDU
  • Cord Retention Brackets
  • Rack Mounting Brackets
  • Owner's Manual

Features

Package Contents: 
  • Monitored PDU3VN10L1530 36-Outlets 8.6kW PDU
  • Cord Retention Brackets
  • Rack Mounting Brackets
  • Owner's Manual


Environmentally Friendly: Yes

Environmental Certification: RoHS

Specification

General Information
ManufacturerTripp Lite
Manufacturer Part NumberPDU3VN10L1530
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product SeriesMonitored
Product ModelPDU3VN10L1530
Product NameMonitored PDU3VN10L1530 36-Outlets 8.6kW PDU
Marketing InformationThe PDU3VN10L1530 10kW 3-Phase Monitored PDU features 48 outlets for distributing network-grade 200/208/240V AC power to rack-mounted network devices, including computers, servers, routers and switches. Outlets are arranged in three separate load banks, each with 16 outlets(14 C13 and two C19) and a dedicated 20A circuit breaker.

A built-in SNMPWEBCARD enables full remote access for power monitoring, configuration, control and notifications 24 hours a day via secure web browser, telnet or SSH, as well as real-time load/current data with billing-grade accuracy(+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent accidental overloads, power loss and downtime. Digital LED display indicates amps, kilowatts, volts and power unbalance percentage, as well as temperature and humidity conditions when using the optional ENVIROSENSE module(sold separately).

Protocols supported include HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Network settings can be assigned automatically or manually.

Ideal for three-phase network configurations in high-density data centers and heavily configured equipment racks, the PDU3VN10L1530 mounts vertically in 0U of rack space using the pre-installed buttons or included hardware. The NEMA L15-30P input plug with 10-foot cord connects to a compatible AC power source, generator or protected UPS.

Product TypePDU
Technical Information
Input ReceptaclesNEMA L15-30P
Output Receptacles
Protection TypeOverload Protection
Power Description
Input Voltage208 V AC
Output Voltage208 V AC
Power Rating8.60 kVA
Management
Management

Protocols:

  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • Telnet
  • SSH
  • FTP
  • DHCP
  • BOOTP
  • NTP
Physical Characteristics
Form FactorVertical Rackmount
Height70"
Width2.2"
Depth3.3"
Weight (Approximate)12.80 lb
Title
ProductTitleTripp Lite PDU 3-Phase Monitored 200/208/240V 10kW L15-30P 42 C13 6 C19 0U - 6 x IEC 60320 C19, 42 x IEC 60320 C13 - 10kW - Zero U Vertical Rackmount"

Warranty Information

Limited Warranty2 Year
Beach Audio Warranty

This product was added to our catalog on Sunday, December 04, 2016.

Code:2-pdu3vn10l1530

NetSuite ecommerce design