Tripp Lite's 120V 20A metered PDU system with Automatic Transfer Switching (ATS) is a 16 outlet PDU with a digital display to indicate total PDU power consumption in amps. Outlets are sequentially turned-on at 250 millisecond intervals when the PDU is first energized from an unpowered state to prevent inrush-related equipment interaction on startup. Supports 1U rackmount installation in a 2 or 4 post rack. Included are 16 NEMA 5-15/20R outlets, and two 12 ft. L5-20P input power cords. Each cord is compatible with both NEMA 5-20R and L5-20R receptacles.Optional integrated ATS is available for use when two separately derived input power sources are available. The attached power cord serves as the primary AC input cable, while the included detachable power cord serves as the optional-use secondary AC input connection. The PDU system passes the primary input power through to connected equipment whenever line voltage and frequency levels are normal. If the primary input source goes outside of these tolerances or fails altogether, the ATS will automatically switch all PDU output to the secondary line sourced input power (when available) to maintain continuous operation of connected loads without reboots or service interruptions. Once the primary power source is restored, the PDU will automatically switch back to primary sourced input power. The dual



Package Contents:
  • PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
  • PDU with attached L5-20P input power cord
  • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
  • Two NEMA L5-20R to NEMA 5-20P plug adapters
  • User manual with warranty information

Features

Package Contents: 
  • PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
  • PDU with attached L5-20P input power cord
  • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
  • Two NEMA L5-20R to NEMA 5-20P plug adapters
  • User manual with warranty information


TAA Compliant

Certifications & Standards: 
  • 60950
  • Class A
  • RoHS Complaint


Environmentally Friendly: Yes

TAA Compliant: Yes

Specification

General Information
ManufacturerTripp Lite
Manufacturer Part NumberPDUMH20AT
Manufacturer Website Addresshttp://www.tripplite.com
Brand NameTripp Lite
Product ModelPDUMH20ATNET
Product NamePDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
Marketing Information

Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Product TypePDU
Technical Information
Input Receptacles2 x NEMA L5-20P
Output Receptacles16 x NEMA 5-15/20R
Power Description
Input Voltage120 V AC
Output Voltage120 V AC
Power Rating2.40 kVA
Management
Management
  • Optional Automatic Transfer Switch (ATS) function enables setup for hot-swappable UPS maintenance bypass
  • Dual UPS protection or dual AC input redundancy for critical single-corded network hardware
  • Slot for optional SNMPWEBCARD accessory to enable remote individual outlet control over IP
Physical Characteristics
Form FactorRack-mountable
Rack Height1U
Number of Cord/Cable2
Cord Length12
Height1.8"
Width17.5"
Depth14.5"
Weight (Approximate)12.20 lb
Title
ProductTitleTripp Lite PDU Metered ATS 120V 20A 5-15/20R 16 Outlet L5-20P Horizontal 1U - 16 x NEMA 5-15/20R - 2.4kVA - 1U Rack-mountable

Warranty Information

Beach Audio Warranty

This product was added to our catalog on Saturday, December 10, 2016.

Code:3-pdumh20at

NetSuite ecommerce design

© 2014 Beach Audio, Inc. All Rights Reserved