Tripplite

Tripp Lite Smartpro Smart2200rm2u 2200va Rack-mountable Ups - 2200va/1920w - 5 Minute Full Load - 4 X Nema 5-15r, 4 X Nema 5-15/20r

(No reviews yet) Write a Review
SKU:
18246002
MPN:
smart2200rm2u
Availability:
Usually ships the same or next business day. In stock at our CA, IL, PA, TX warehouses.
Shipping:
Calculated at Checkout
Stock Update:
04/23/2024 12:18:19 AM PST
  • Main
  • Right
  • Rear
  • Front
  • Left
  • Alternate-Image1
  • Alternate-Image5
  • Alternate-Image4
  • Alternate-Image3
  • Alternate-Image2
$1,120.90
Stock Update:
04/23/2024 12:18:19 AM PST

Description



This item is brand-new, factory sealed.

2200VA / 2.2kVA / 1920 watt line interactive UPS system with high power factor for server, network and telecommunications equipment. 2U rackmount or tower form factor with an installed depth of only 19 inches. Uninterruptible Power Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage variations. Line interactive Automatic Voltage Regulation (AVR) offers two levels of voltage boost during brownouts and one level of voltage cut during overvoltages to maintain regulated 100, 110, 120v selectable output over an input range of 83-145V.



Includes NEMA 5-20P input plug and both NEMA 5-15R and 5-15/20R output receptacles. Network-grade AC surge and noise suppression. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables full integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling.



Emergency Power Off (EPO) interface. Integrated 3-bank PDU switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.OUTPUT
Output Volt Amp Capacity (VA): 2200
Output kVA capacity (kVA): 2.2
Output Watt Capacity (watts): 1920
Output kW capacity: 1.92
Output power factor: 0.87
Output Capacity Details: Output de-rates to 1800w at 110V and 1670w at 100V nominal settings
Nominal Output Voltage(s) Supported: 100V 110V 120V
Nominal Voltage details: 120V default (voltage selection via back panel dipswitches)
Frequency compatibility :50 / 60 Hz
Frequency compatibility details: Supports 60Hz at 110V and 120V nominal and 50/60Hz (auto-sensing) at 100V nominal.
Output voltage regulation (line mode): -14%, +6%
Output voltage regulation (Battery mode): +/- 5%
Built-in UPS output receptacles: 4 x 5-15R outlet(s) 4 x 5-15/20R outlet(s)
Built-in controllable switched load banks: Three switchable single-outlet 5-15R load banks
Basic PDU options: PDU1220 (1U / 13 5-15/20R outlets) PDUNV (1U / 2 C19, 12 C13 outlets) PDUV20 (0U / 12 5-15/20R outlets) PDU40TDUAL (0U / 40 5-15/20R outlets)
Metered PDU options: PDUMH20 (1U / 13 5-15/20R outlets) PDUMH20AT (1U / 16 5-15/20R outlets) PDUMV20 (0U / 16 5-15/20R outlets) PDUMV40 (0U / 32 5-15/20R outlets)
Switched PDU options: PDUMH20ATNET (1U / 16 5-15/20R outlets) PDUMV20NET (0U / 24 5-15/20R outlets)
External PDU redundancy options: Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS models only
Output AC waveform (AC mode): Sine wave
Output AC waveform (battery mode): Sine wave
INPUT
Rated input current (at maximum load) :16A (120V), 16.4A (110V), 16.7A (100V)
Nominal Input Voltage(s) Supported :100V AC 110V AC 120V AC
UPS input connection type: 5-20P
Input circuit breake:r 20A
UPS Input cord length (ft.): 10
UPS Input cord length (m) :3
Recommended Electrical Service :20A 120V
BATTERY
Full load runtime (minutes): 5 min. (1920w)
Half load runtime (minutes): 13 min. (960w)
DC system voltage (VDC): 48
Battery recharge rate (included batteries) :Less than 4.5 hours from 10% to 90%
Replacement battery cartridge (internal UPS battery replacement): RBC94-2U
Battery Access: Front panel battery access door
Battery replacement description :Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description: Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage correction: Voltage reduction of 12% applies when input is between 127 and 145 (120V), 116 and 133 (110V), 106 and 121 (100V)
Undervoltage correction: Voltage boost of 12% applies when input voltage is between 96 and 108 (120V), 87 and 99 (110V), 83 and 90 (100V)
Severe undervoltage correction: Voltage boost of 24% applies when input voltage is between 83 and 95 (120V only)
LEDS ALARMS SWITCHES
LED Indicators: 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms: Audible alarm indicates power-failure, overload and low-battery conditions
Alarm cancel operation: Power-fail alarm can be silenced using alarm-cancel switch once silenced, alarm will re-sound to indicate low-battery status
Switches: 2 Switches control off/on power status and alarm-cancel/self-test operation rear panel protected switches support nominal voltage selection
SURGE / NOISE SUPPRESSION
UPS AC suppression joule rating: 570
UPS AC suppression response time: Instantaneous
EMI / RFI AC noise suppression :Yes
PHYSICAL
Installation form factors supported with included accessories: 4 post 19 inch rackmount (mounting rail kit included)
Installation form factors supported with optional accessories: 2 post rackmount (2POSTRMKITWM) Wallmount (2POSTRMKITWM) Tower (2-9USTAND)
Primary form factor: Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches): 3.5 x 17.5 x 19
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) :8.9 x 44.4 x 48.3
Installed whole system total rack space height (rack spaces): 2U
Secondary form factor: Tower (requires 2-9USTAND)
Installed whole system dimensions in secondary form factor (height x width x depth / inches): 17.5 x 3.5 x 19
UPS dimensions in secondary form factor (height x width x depth / cm): 44.4 x 8.9 x 48.3
UPS / Power Module weight (lbs) :64
UPS / Power Module weight (kg): 29.1
UPS Shipping dimensions (height x width x depth / inches): 9 x 23.5 x 20
UPS Shipping dimensions (height x width x depth / cm) :22.9 x 59.7 x 50.8
Shipping weight (lbs) :72
Shipping weight (kg) :32.7
UPS housing material :Steel
Cooling method :Fan
COMMUNICATIONS
Communications interface: USB (HID enabled) DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface
Network monitoring port description :Supports detailed monitoring of UPS and site power conditions
PowerAlert software: Included
Communications cable: USB and DB9 cabling included
WatchDog compatibility: Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time :2-4 milliseconds
Low voltage transfer to battery power (setpoint) :83 (120V), 87 (110V), 83 (100V)
High voltage transfer to battery power (setpoint): 145 (120V), 133 (110V), 121 (100V)
CERTIFICATIONS
UPS Certifications :Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) ROHS (Reduction of Hazardous Substances)

Features

Package Contents:   
  • SmartPro SMART2200RM2U 1950VA Rack/Tower UPS
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions

  •  

    Certifications & Standards:   
    • UL1778 (USA)
    • CSA (Canada)
    • NOM (Mexico)
    • FCC Part 15 Category A (EMI)

     

    Environmental Certification:

    ENERGY STAR 2.0
    RoHS

     

    TAA Compliant:   
    Yes

     

    Environmentally Friendly:   
    Yes

     

    Software Included:   
    PowerAlert Software

     

    Energy Star:   
    Yes

     

    Recycled:   
    No

     

    Country of Origin:   
    China

     

    Specs

    Power Description
    Load Capacity (Watt)1950 W
    Input Frequency60 Hz
    Output Power Factor1
    Surge Energy Rating380 J
    Input Voltage Range70 V AC - 153 V AC
    Input Voltage120 V AC
    Output Voltage
    Load Capacity (VA)1950 VA
    Input Current16.40 A
    Waveform TypePure Sine Wave
    Output Frequency60 Hz
    Physical Characteristics
    Form FactorRack/Tower
    Weight (Approximate)65.30 lb
    Height3.4"
    Width17.2"
    Depth23.7"
    Rack Height2U
    Warranty
    Additional Warranty Information2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty.
    Limited Warranty3 Year
    Controls/Indicators
    Status Indicators<p><b>5 Front Panel Leds:</b></p><ul><li>Green Power Led</li><li>Green Voltage Correction Led</li><li>3 Color Battery Charge Led</li><li>3 Color Output Load Led</li><li>Red Battery Warning Led</li></ul>
    Battery Information
    Backup/Run Time (Full Load)4 Minute
    DC System Voltage72 V DC
    Replaceable BatteryYes
    Battery ChemistryLead Acid
    Hot SwappableYes
    Backup/Run Time (Half Load)12 Minute
    Typical Battery Recharge Time4.50 Hour
    Battery CharacteristicsValve-regulated
    Display & Graphics
    DisplayLCD
    General Information
    Brand NameTripp Lite by Eaton
    Manufacturer Website Addresshttps://tripplite.eaton.com/
    Marketing Information1.95kVA/1.95kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments
    This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your IT equipment or destroy data. The SMART2200RM2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment.
    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately).
    Optional LX Platform Network Management Card Allows Remote Access 24/7
    The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.
    NEMA Outlets Protect Your Connected Components
    One L5-20R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split into two independently switchable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
    Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
    AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART2200RM2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
    More from the Manufacturer
    Product TypeLine-interactive UPS
    Product NameSmartPro SMART2200RM2U 1950VA Rack/Tower UPS
    ManufacturerTripp Lite by Eaton
    Manufacturer Part NumberSMART2200RM2U
    Product ModelSMART2200RM2U
    Product LineSmartPro
    Packaged Quantity1 Each
    Technical Information
    Receptacle Type
    Receptacle Detail
    PhaseSingle Phase
    EMI/RFI Noise FilterYes
    Emergency Power OFFYes
    Transfer Time4 ms
    Energy SavingGreater than 95% efficiency - GREEN UPS; Individually controllable load banks
    Overload ProtectionYes
    Plug/Connector TypeNEMA 5-20P
    Cord Length10 ft
    Protection Type
    Application/Usage
    AVRYes
    Management
    Network ManagementSNMP/Web
    Alarm
    Interfaces/Ports
    USBYes
    EPO PortYes
    Serial PortYes
    USB (HID Compliant) PortYes
    Environmental Conditions
    Maximum Storage Elevation32808 ft
    Sound Emission (A-Weighted)45 dB(A)
    Maximum Operating Temperature104&deg;F (40&deg;C)
    Minimum Operating Temperature32&deg;F (0&deg;C)
    Storage Temperature5&deg;F (-15&deg;C) - 122&deg;F (50&deg;C)
    Maximum Operating Elevation10000 ft

    View AllClose

    Warranty Information

    All Items are Brand New, Factory Sealed and come with a standard warranty. [Read our policies]
    View AllClose

    0 Reviews

    View AllClose
    Main
    Tripp Lite Smartpro Smart2200rm2u 2200va Rack-mountable Ups - 2200va/1920w - 5 Minute Full Load - 4 X Nema 5-15r, 4 X Nema 5-15/20r
    $1,120.90