Description



This item is brand-new, factory sealed.

Tripp Lite PDU Hot Swap with Manual Bypass 200-240V 16A 5 C13 2 C20 1URM (PDUBHV201U)
  • BYPASS PDU RECOMMENDED FOR MAINTAINING CONTINUOUS POWER DURING UPS MAINTENANCE: Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200240V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDUs bypass switch, permitting maintenance or equipment replacement with no interruption of performance.
  • FEATURES DUAL INPUTS AND A MANUAL TRANSFER SWITCH: The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.
  • ECO SWITCHING FEATURE ENABLES COST-CUTTING POWER SAVINGS: By enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode.
  • MOUNTS INTO 1U OF RACK SPACE OR WALL: Use the included mounting hardware to install the PDUBHV201Us all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
  • Package Dimensions: 21.46 x 8.07 x 5.12 inches
  • Item Weight: 6.61 pounds

Bypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200250V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDUs bypass switch, permitting maintenance or equipment replacement with no interruption of performance. Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption. Optional ECO Switching Feature Enables Cost-Cutting Power Savings By enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode. Mounts into 1U of Rack Space or on a Wall Use the included mounting hardware to install the PDUBHV201Us all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.



Package Contents:
  • PDUBHV201U 6-Outlets PDU
  • 2 x C19-to-C20 Power Cables
  • Mounting Hardware
  • Owner's Manual

Features

Package Contents:   
  • PDUBHV201U 6-Outlets PDU
  • 2 x C19-to-C20 Power Cables
  • Mounting Hardware
  • Owner's Manual

 

Environmentally Friendly:   
Yes

 

Environmental Compliance:   
Restriction of Hazardous Substances (RoHS)

 

Country of Origin:   
China

 

Specs

Power Description
Power Rating (Watt)3800 W
Input Voltage Range200 V AC - 250 V AC
Input Voltage230 V AC
Output Voltage Range200 V AC - 250 V AC
Input Current16 A
Physical Characteristics
Form FactorHot-swappable
Weight (Approximate)5.20 lb
Mount Type
Height1.7"
Mounting OrientationHorizontal
Width17.2"
Rack Height1U
Depth3.9"
Warranty
Limited Warranty2 Year
General Information
Brand NameTripp Lite by Eaton
Manufacturer Website Addresshttp://www.eaton.com
Marketing InformationBypass PDU Recommended for Maintaining Continuous Power During UPS Maintenance
Keeping mission-critical data center equipment operating at its optimal level often means scheduled maintenance. But what if you are unable to afford the costly downtime involved in powering down for regular upkeep? This 200-250V 16A single-phase hot-swap PDU works in conjunction with your UPS system to keep everything running 24/7/365. It allows you to manually transfer connected equipment to utility power via the PDU's bypass switch, permitting maintenance or equipment replacement with no interruption of performance.
Features Dual Inputs and a Manual Transfer Switch for Uninterrupted Operation
The PDUBHV201U features two C20 inlets that connect to separate UPS and utility input power sources with user-supplied power cables or the included C19-to-C20 cables. The manual transfer switch allows PDU output power to flow from either input. Flip the switch to Bypass to replace the UPS and flip back to Normal once the maintenance or UPS replacement is complete. Equipment connected to the outlets will continue to operate without interruption.
Optional ECO Switching Feature Enables Cost-Cutting Power Savings
By enabling the ECO power saving feature, you can power off a single bank of four controlled C13 outlets all at once when the devices connected to the master C13 and C19 outlets are powered off or go into a low-power consumption mode.
Mounts into 1U of Rack Space or on a Wall
Use the included mounting hardware to install the PDUBHV201U's all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall.
Product TypePDU
Product NamePDUBHV201U 6-Outlets PDU
ManufacturerEaton Corporation
Manufacturer Part NumberPDUBHV201U
Product ModelPDUBHV201U
Technical Information
Plug/Connector Detail2 x IEC 60320 C20
Receptacle Type
Receptacle Detail
PhaseSingle Phase
Plug/Connector TypeIEC 60320 C20
PDU TypeManual Bypass