Description
This item is brand-new, factory sealed.
CyberPower MBP63A2 Maintenance Bypass PDU, 200-240V/63A, 3 Outlets, 2U Rackmount- 3.3 foot AC cord or hardware terminal block connect to output power of UPS; 1 NEMA L6-20R outlet, 1 NEMA L6-30R outlet and 1 Hardwire Terminal Block
- Compatible with the OL5KRTHD, OL6KRTHD
- Manual transfer switch controls PDU input power source, allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance
- 200-240VAC - 63A electrical capacity, Rugged, industrial-grade metal housing, 2U Rackmount with mounting hardware
- THREE YEAR LIMITED LIFETIME WARRANTY
- Package Dimensions: 20.5 x 17.8 x 7.1 inches
- Item Weight: 8.8 pounds
Designed for datacenters and other electrically demanding applications, the CyberPower MBP63A2 Maintenance Bypass Power Distribution Unit (MBP PDU), allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The MBP63A2 provides 208V nominal output to (1) NEMA L6-20R, (1) NEMA L6-30R and (1) Hardwire Terminal Block receptacle. Depending on UPS model, either a 3.3-foot AC cord or hardwire terminal block connects to the output power of the UPS. The UPS draws input power from the MBP63A2 separate from the outlets or terminal block for connected devices. When the switch on the front of the MBP63A2 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active. Rugged, industrial-grade metal housing protects the MBP63A2. With a 2U form factor, this PDU can be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration. The MBP63A2 is UL and RoHS compliant. A three-year limited warranty covers the PDU.
Package Contents:
- MBP63A2 3-Outlet PDU
- UPS Mounting Hardware
Features
- MBP63A2 3-Outlet PDU
- UPS Mounting Hardware
Certifications & Standards:
UL 1778
Additional Information:
- Inlet To UPS Input: (1) Terminal Block
- Inlet To UPS Output: (1) Terminal Block
- Inlet To Utility Power: (1) Terminal Block
- Management Cable: MBP Detection Cable 3.3 ft.
- Material of Construction: Metal
- Operating Relative Humidity: 0 - 90 % (non-condensing)
- Operating Temperature: 32 - 104 °F (0 - 40 °C)
Environmentally Friendly:
Yes
Compatibility:
CyberPower Smart App Online:
- OL5KRTHD
- OL6KRTHD
Environmental Compliance:
Restriction of Hazardous Substances (RoHS)
Country of Origin:
China
Specs
| Power Description | |
| Input Voltage Range | 200 V AC - 240 V AC |
| Input Voltage | 230 V AC |
| Output Voltage | 208 V AC |
| Input Current | 63 A |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 8.80 lb |
| Cord Length | 3.30 ft |
| Height | 3.4" |
| Mounting Orientation | Horizontal/Vertical |
| Width | 17" |
| Rack Height | 2U |
| Depth | 4.9" |
| Warranty | |
| Limited Warranty | 3 Year |
| General Information | |
| Brand Name | CyberPower |
| Manufacturer Website Address | https://www.cyberpowersystems.com/ |
| Marketing Information | Designed for datacenters and other electrically demanding applications, the CyberPower MBP63A2 Maintenance Bypass Power Distribution Unit (MBP PDU), allows the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS. The MBP63A2 provides 208V nominal output to (1) NEMA L6-20R, (1) NEMA L6-30R and (1) Hardwire Terminal Block receptacle. Depending on UPS model, either a 3.3-foot AC cord or hardwire terminal block connects to the output power of the UPS. The UPS draws input power from the MBP63A2 separate from the outlets or terminal block for connected devices. When the switch on the front of the MBP63A2 is turned from Normal to Bypass, or from Bypass to Normal, the power that the MBP supplies to connected devices moves from one input power source to another. The LED display indicates which power source is active. Rugged, industrial-grade metal housing protects the MBP63A2. With a 2U form factor, this PDU can be mounted horizontally or vertically in a standard server rack, on a wall or in a tower configuration. The MBP63A2 is UL and RoHS compliant. A three-year limited warranty covers the PDU. |
| Product Condition | New |
| Product Type | PDU |
| Product Name | MBP63A2 3-Outlet PDU |
| Manufacturer | CyberPower Systems, Inc |
| Manufacturer Part Number | MBP63A2 |
| Product Model | MBP63A2 |
| Product Series | Maintenance Bypass |
| Technical Information | |
| Plug/Connector Detail | 1 x Hardwire Terminal Block |
| Receptacle Type |
|
| Receptacle Detail |
|
| Plug/Connector Type | Hardwire Terminal Block |
| PDU Type | Hot-swappable |