Description



This item is brand-new, factory sealed.

CyberPower PDU44005 Switched ATS PDU, 100-120V,20A (Derated to 16A), 10 Outlets, 1U Rackmount
  • 200-240V/20A (derated to 16A) Metered ATS Power Distribution Unit (PDU) delivers AC power to servers, equipment, network/telecom devices; AUTOMATIC TRANSFER SWITCH: Dual power cords provide redundant power sources to devices with single power supplies
  • 8 REAR IEC-320 C13, TWO REAR IEC-320 C19 OUTLETS: Can be turned on/off, recycled on demand, at set times for remote rebooting, load shedding, power sequencing, & locking out unauthorized loads; INPUT: Two IEC-320 C20 input plugs with 10 foot power cords
  • SELECTABLE COLOR LCD PANEL: Displays immediate, detailed information on PDU conditions, including amperage, voltage, KW, IP Address, etc.; COMPATIBLE WITH: Sine wave AC power sources; NOT COMPATIBLE WITH: simulated sine wave AC power sources
  • REMOTE AND LOCAL MONITORING: User can track PDU vitals both offsite and onsite; Provides control to turn on/off individual outlets or circuits; AUTOMATIC EVENT NOTIFICATIONS: Provides immediate updates about power events via email, SMS, or SNMP traps
  • 1U RACKMOUNT: With durable metal housing; UPGRADEABLE FIRMWARE: allows users to download firmware updates to programs that run the PDU; 3-YEAR LIMITED WARRANTY
  • Package Dimensions: 21.65 x 15.67 x 4.9 inches
  • Item Weight: 14.5 pounds

Ensure continued operation of critical devices with the CyberPower PDU44005 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management. The PDU44005 supports inputs between 200-240V and includes (8) IEC C13 and (2) IEC C19 outlets. Dual IEC C20 power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44005 is protected by a three-year limited warranty.

Features

UL Listed:   
Yes

 

Certifications & Standards:   
  • UL62368
  • FCC Class A
  • cTUVus
  • CE
  • UKCA

 

Additional Information:   
  • Physical Dimensions - (WxHxD) (cm) : 43.31 x 4.45 x 21.46 (cm)
  • Physical Dimensions - (WxHxD) (in) : 17.05 x 1.75 x 8.45 (in)
  • Physical Dimensions - (WxHxD) (mm) : 433 x 44 x 215 (mm)
  • Weight (kg) : 3.76
  • Weight (lb) : 8.3
  • Shipping Dimensions - (WxHxD) (cm) : 54.99 x 12.45 x 39.8 (cm)
  • Shipping - Dimensions (WxHxD, in) : 21.65 x 4.9 x 15.67 (in)
  • Shipping - Dimensions (WxHxD, mm) : 549.91 x 124.46 x 398.02 (mm)
  • Shipping - Weight (kg) : 6.58
  • Shipping - Weight (lb) : 14.5
  • Cord Length : 10 ft (3.0 m)
  • Derated Input Current : 16 A
  • Input Frequency Range : 50 Hz - 60 Hz
  • Input Overload Protection : 20A x 2
  • Input Plug Type : 2 x IEC-320 C20
  • Maximum Input Current : 20A
  • Nominal Input Voltage : 200 - 240 VAC
  • Phase : Single Phase
  • Plug Style : Straight (Socket)
  • Nominal Output Voltage : 200 - 240 VAC
  • Outlet Banks : 1
  • Outlets - Total : 10
  • Outlet Type COMPUTED : 8 - IEC-320 C13
  • Overload Protection : None
  • Power Source Transfer Time : 2-7 ms
  • Source Failure Detection Time : 2-3 ms
  • Total Transfer Time : <10 ms
  • Environmental Sensor : Optional, via RJ45
  • Hardware Connection Port : Ethernet (RJ45)
  • LCD : Multifunction LCD
  • LED Indicators : Source Status
  • Modular Expandability (Cascading) : Yes, via RJ45
  • Outlet switching : Yes
  • SNMP / HTTP Remote Monitoring : IPv4, TCP/IP, UDP, SNMPv1, HTTP, NTP, DNS, Telnet, DHCP, SMTP, FTP, IPv6, SNMPv3, HTTPs, SSH, SSL, TLS, LDAP(S), RADIUS, Syslog, CLI, Windows AD
  • Upgradeable firmware : Yes
  • Color : Black
  • Cord Retention Tray/Cord Organizers : Yes
  • External Site Ground Pin : Yes
  • Form Factors Supported : 1U Rackmount
  • Material of Construction : Metal
  • Rack Height : 1U
  • Style : Rackmount
  • Operating Elevation : 0 - 13123 ft (0 - 4000 m)
  • Operating Relative Humidity : 0 - 95 % (non-condensing)
  • Operating Temperature : 32 - 113 °F (0 - 45 °C)
  • Storage Elevation : 0 - 49213 ft (0 - 14999 m)
  • Storage Temperature : 5 - 131 °F (-15 - 55 °C)
  • Environmental : RoHS Compliant
  • Safety : UL62368 : FCC Class A : cTUVus/CE/UKCA
  • Extended Warranty Option : WEXT5YR-PDU1B
  • Product Warranty : 3 Year Limited Warranty

  •  

    Environmentally Friendly:   
    Yes

     

    Application/Usage:

    Data Center
    Network Closet

     

    Environmental Compliance:   
    Restriction of Hazardous Substances (RoHS)

     

    Country of Origin:   
    China

     

    Specs

    Power Description
    Input Frequency60 Hz
    Input Voltage Range200 V AC - 240 V AC
    Input Voltage230 V AC
    Circuit BreakerYes
    Output Voltage230 V AC
    Output Voltage Range200 V AC - 240 V AC
    Input Current20 A
    Physical Characteristics
    Product MaterialMetal
    Form FactorRack
    Weight (Approximate)8.29 lb
    Cord Length10 ft
    Product ColorBlack
    Mount TypeRack-mountable
    Height1.8"
    Color FamilyBlack
    Mounting OrientationHorizontal
    Width17.1"
    Rack Height1U
    Depth8.5"
    Warranty
    Limited Warranty3 Year
    Interfaces/Ports
    Network (RJ-45)Yes
    General Information
    Brand NameCyberPower
    Manufacturer Website Addresshttps://www.cyberpowersystems.com/
    Marketing Information Ensure continued operation of critical devices with the CyberPower PDU44005 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.
    The PDU44005 supports inputs between 200-240V and includes (8) IEC C13 and (2) IEC C19 outlets. Dual IEC C20 power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44005 is protected by a three-year limited warranty.
    Product TypePDU
    Product NamePDU44005
    ManufacturerCyberPower Systems, Inc
    Manufacturer Part NumberPDU44005
    Product ModelPDU44005
    Product SeriesSwitched ATS PDU
    Technical Information
    DesignModular
    Plug/Connector Detail2 x IEC 60320 C20
    Receptacle Type
    Receptacle Detail
    PhaseSingle Phase
    Plug/Connector TypeIEC 60320 C20
    PDU TypeSwitched
    Protection TypeOverload Protection
    Features
    Management
    Remote Outlet SwitchingYes
    Management<ul> <li>IPv4</li> <li>TCP/IP</li> <li>UDP</li> <li>SNMPv1</li> <li>HTTP</li> <li>NTP</li> <li>DNS</li> <li>Telnet</li> <li>DHCP</li> <li>SMTP</li> <li>FTP</li> <li>IPv6</li> <li>SNMPv3</li> <li>HTTPs</li> <li>SSH</li> <li>SSL</li> <li>TLS</li> <li>LDAP(S)</li> <li>RADIUS</li> <li>Syslog</li> <li>CLI</li> <li>Windows AD</li> </ul>
    Environmental Conditions
    Maximum Storage Temperature131&deg;F (55&deg;C)
    Maximum Operating Temperature113&deg;F (45&deg;C)
    Minimum Storage Temperature5&deg;F (-15&deg;C)
    Minimum Operating Temperature32&deg;F (0&deg;C)