Raymarine
Raymarine E70099 Autopilot Actuator Control Unit
- SKU:
- 18329610
- MPN:
- e70099
- Availability:
- Usually ships the same or next business day. In stock at our CA, Fl, MI, PA, WA warehouses.
- Shipping:
- Calculated at Checkout
- Stock Update:
- 02/12/2026 02:53:33 PM PST
- Stock Update:
- 02/12/2026 02:53:33 PM PST
Description
This item is brand-new, factory sealed.
Raymarine Evolution ACU Specifications| Model | ACU-100 | ACU-200 | ACU-300 | ACU-400 |
| E70098 | E70099 | E70139 | E70100 | |
| | ||||
| Drive Current Output | Maximum continuous 7 A at supply voltage | Maximum continuous 15 A at supply voltage | Maximum continuous 5 A at supply voltage | Maximum continuous 30 A at supply voltage |
| Drive Clutch Output | No clutch connection | Up to 2.0 A continuous, selectable between 12 /24 V | No clutch connection |
|
| Connections |
|
|
|
|
| Nominal supply voltage | 12 V | 12 V or 24 V | ||
| Operating voltage range | 10.8 V to 15.6 V dc | 10.8 V to 31.2 V dc | ||
| Power consumption (standby) - main power supply | 300 mA (12V) | 300 mA (12/24 V) | ||
| Power consumption (standby) - SeaTalkng power supply | No power supply to SeaTalkng&nbs p; | 20 mA (12V) | ||
| SeaTalkng LEN (Load Equivalency Number) | 1 | |||
| SeaTalkng Power out | No power supply to SeaTalkng | 3 A at 12 V (fuse protected at 3 A) | ||
| Data connections | SeaTalkng | |||
| Installation environment | Operating temperature: -20°C to +55°C (-4°F to +131°F) Storage temperature: -30°C to +70°C (-22°F to +158°F) Relative humidity: max 93% | |||
| Waterproof rating | Connector panel: IPX2 Drive electronics: IPX6 | Drip resistant | ||
| Dimensions (W x H x D) | 180 mm x 140 mm x 52 mm (7.1 in x 5.5 in x 2.0 in) | 285 mm x 211.5 mm x 64.5 mm (11.2 in x 8.3 in x 2.5 in) | ||
| Weight | 0.6 kg (1.32 lbs) | 2.2kg (4.84 lbs) | ||
| Conformance | Europe: 2004/108/EC Australia and New Zealand: C-Tick, Compliance Level 2 | |||
Features
- Drive Current Output: Maximum continuous 15 A at supply voltage
- Drive Clutch Output: Up to 2.0 A continuous, selectable between 12 /24 V
- Nominal supply voltage: 12 V or 24 V
- Operating voltage range: 10.8 V to 31.2 V dc
- Power consumption (standby) - main power supply: 300 mA (12/24 V)
- Consumption (standby) - SeaTalkng power supply: 20 mA (12V)
- SeaTalkng LEN (Load Equivalency Number): 1
- SeaTalkng Power out: 3 A at 12 V (fuse protected at 3 A)
- Rudder reference sensor
- Sleep switch
- Power
- Drive motor
- Drive clutch
- Ground
Specs
| Physical Characteristics | |
| Weight (Approximate) | 4.85 lb |
| Height | 8.3" |
| Width | 11.2" |
| Depth | 2.5" |
| General Information | |
| Brand Name | Raymarine |
| Manufacturer Website Address | http://www.raymarine.com |
| Product Type | Actuator Control Unit |
| Product Name | ACU-200 Actuartor Control Unit |
| Manufacturer | Raymarine, Inc |
| Manufacturer Part Number | E70099 |
| Product Model | ACU-200 |
Warranty Information