Tripp Lite

Tripp Lite PDU Monitored 208/240V 30A 36 C13; 6 C19 L6-30P LX Interface 0U (pdumnv30hv2lx)

(No reviews yet) Write a Review
SKU:
18243765
MPN:
pdumnv30hv2lx
Availability:
Out of stock
Stock Update:
12/02/2025 01:28:05 PM PST
  • Main
  • Front
  • Alternate-Image8
  • Alternate-Image6
  • Alternate-Image5
  • Alternate-Image4
  • Alternate-Image3
  • Alternate-Image2
  • Alternate-Image1
  • Alternate-Image9
  • Alternate-Image7

Out of stock

Stock Update:
12/02/2025 01:28:05 PM PST

Description



This item is brand-new, factory sealed.

The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.

The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

Package Contents:
  • PDUMNV30HV2LX 42-Outlet PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-mounting Hardware
  • Mounting Bracket Accessory
  • Owner's Manual

Features

Package Contents:   
  • PDUMNV30HV2LX 42-Outlet PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-mounting Hardware
  • Mounting Bracket Accessory
  • Owner's Manual

 

TAA Compliant:   
Yes

 

Environmentally Friendly:   
Yes

 

Environmental Compliance:   
Restriction of Hazardous Substances (RoHS)

 

Country of Origin:   
Taiwan

 

Specs

Power Description
Power Rating (Watt)5800 W
Input Voltage230 V AC
Output Voltage
Input Current30 A
Physical Characteristics
Weight (Approximate)15 lb
Mount TypeRack-mountable
Height70"
Mounting OrientationVertical
Width2.2"
Rack Height0U
Depth2.6"
Warranty
Limited Warranty2 Year
General Information
Brand NameEaton
Manufacturer Website Addresshttp://www.eaton.com
Marketing InformationThe PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.
The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
More from the Manufacturer
Product TypePDU
Product NamePDUMNV30HV2LX 42-Outlet PDU
ManufacturerEaton Corporation
Manufacturer Part NumberPDUMNV30HV2LX
Product ModelPDUMNV30HV2LX
Technical Information
Receptacle Type
Receptacle Detail
PhaseSingle Phase
Plug/Connector TypeNEMA L6-30P
PDU TypeMonitored
Management
Management<b>Protocols:</b><br /> <ul> <li>IPv4</li> <li>IPv6</li> <li>HTTP</li> <li>HTTPS</li> <li>SMTP</li> <li>SNMPv1</li> <li>SNMPv2</li> <li>SNMPv3</li> <li>telnet</li> <li>SSH</li> <li>FTP</li> <li>DHCP</li> <li>NTP</li> </ul>

View AllClose

Warranty Information

All Items are Brand New, Factory Sealed and come with a standard warranty. [Read our policies]
View AllClose

0 Reviews

View AllClose
Main