cyberpower systems

CyberPower Metered ATS PDU PDU44007 19-Outlets PDU

(No reviews yet) Write a Review
SKU:
19274978
MPN:
pdu44007
Availability:
Usually ships the same or next business day. In stock at our CA warehouse.
Shipping:
Calculated at Checkout
Stock Update:
07/11/2026 12:06:45 AM PST
  • Main
  • Right
  • Rear
  • Left
  • Alternate-Image2
  • Alternate-Image1
  • Alternate-Image3
$1,345.95
Stock Update:
07/11/2026 12:06:45 AM PST
Frequently bought together:

Description



This item is brand-new, factory sealed.

Ensure continued operation of critical devices with the CyberPower PDU44007 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.

The PDU44007 supports inputs between 200-240V and includes (16) IEC C13, (2) IEC C19, and (1) NEMA L6-30R outlets. Dual NEMA L6-30P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44007 is protected by a three-year limited warranty.

Features

UL Listed:   
Yes

 

Certifications & Standards:   
UL62368 via cTUVus

 

Additional Information:   
  • Cord Retention Tray/Cord Organizers: Yes
  • Derated Input Current: 24 A
  • Environmental Sensor: Optional, via RJ45
  • External Site Ground Pin: Yes
  • LED Indicators: Source Status
  • Modular Expandability (Cascading): Yes, via RJ45
  • Operating Elevation: 0 - 13123 ft (0 - 4000 m)
  • Storage Elevation: 0 - 49213 ft (0 - 14999 m)
  • Operating Relative Humidity: 0 - 95 % (non-condensing)
  • Outlet Banks: 2
  • Outlets - Total: 19
  • Overload Protection: 20A x 2
  • Plug Style: Straight
  • Power Source Transfer Time: 2-7 ms
  • Source Failure Detection Time: 2-3 ms
  • Total Transfer Time: <10 ms
  • Upgradeable firmware: Yes

 

Environmentally Friendly:   
Yes

 

Application/Usage:

Data Center
Network Closet

 

Environmental Compliance:   
Restriction of Hazardous Substances (RoHS)

 

Country of Origin:   
China

 

Specs

Power Description
Input Frequency60 Hz
Input Voltage Range200 V AC - 240 V AC
Input Voltage230 V AC
Circuit BreakerYes
Output Voltage
Output Voltage Range200 V AC - 240 V AC
Input Current30 A
Physical Characteristics
Product MaterialMetal
Form FactorRack
Weight (Approximate)17.60 lb
Cord Length10 ft
Product ColorBlack
Mount TypeRack-mountable
Height3.5"
Color FamilyBlack
Mounting OrientationHorizontal
Width17.1"
Rack Height2U
Depth8.5"
Warranty
Limited Warranty3 Year
Interfaces/Ports
Network (RJ-45)Yes
General Information
Brand NameCyberPower
Manufacturer Website Addresshttps://www.cyberpowersystems.com
Marketing Information Ensure continued operation of critical devices with the CyberPower PDU44007 Switched ATS PDU. Ideal for data centers and network closets, this unit provides power redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. Additionally, this unit offers real time remote and local monitoring and outlet management.
The PDU44007 supports inputs between 200-240V and includes (16) IEC C13, (2) IEC C19, and (1) NEMA L6-30R outlets. Dual NEMA L6-30P power cords are plugged into separate power sources (A and B), and information about each power source is clearly displayed on the front panel LED indicator lights. Other features include an LCD with selectable background color, built-in web interface, and power event notifications. The CyberPower PDU44007 is protected by a three-year limited warranty.
More from the Manufacturer
Product TypePDU
Product NamePDU44007
ManufacturerCyberPower Systems, Inc
Manufacturer Part NumberPDU44007
Product ModelPDU44007
Product SeriesSwitched ATS PDU
Technical Information
Plug/Connector Detail2 x NEMA L6-30P
Receptacle TypeIEC 60320 C13
Receptacle Detail16 x IEC 60320 C13
PhaseSingle Phase
Plug/Connector TypeNEMA L6-30P
PDU TypeSwitched
Locking ReceptaclesCord Retention Tray
Protection TypeOverload Protection
FeaturesLCD Display
Management
Remote Outlet SwitchingYes
Management<ul><li>IPv4</li><li>TCP/IP</li><li>UDP</li><li>SNMPv1</li><li>HTTP</li><li>NTP</li><li>DNS</li><li>Telnet</li><li>DHCP</li><li>SMTP</li><li>FTP</li><li>IPv6</li><li>SNMPv3</li><li>HTTPs</li><li>SSH</li><li>SSL</li><li>TLS</li><li>LDAP(S)</li><li>RADIUS</li><li>Syslog</li><li>CLI</li><li>Windows AD</li></ul>
Environmental Conditions
Maximum Storage Temperature131&deg;F (55&deg;C)
Maximum Operating Temperature113&deg;F (45&deg;C)
Minimum Storage Temperature5&deg;F (-15&deg;C)
Minimum Operating Temperature32&deg;F (0&deg;C)

View AllClose

Warranty Information

All Items are Brand New, Factory Sealed and come with a standard warranty. [Read our policies]
View AllClose

0 Reviews

View AllClose
Main
CyberPower Metered ATS PDU PDU44007 19-Outlets PDU
$1,345.95