Tripp Lite UPS Smart 750VA 450W Rackmount AVR 120V Pure Sign Wave USB DB9 SNMP 2URM (SMART750RMXL2U)
- SKU:
- 18142123
- MPN:
- smart750rmxl2u
- Availability:
- Usually ships the same or next business day. In stock at our CA, PA, TX warehouses.
- Shipping:
- Calculated at Checkout
- Stock Update:
- 12/10/2025 03:24:03 PM PST
- Stock Update:
- 12/10/2025 03:24:03 PM PST
Description
This item is brand-new, factory sealed.
MODEL- SMART750RMXL2U VENDOR- TRIPPLITE FEATURES- SmartPro Rack/Tower UPS System- Black Intelligent, line interactive power management system! 750VA line interactive, extended-run 2U rack/tower UPS; Maintains sine-wave 120V nominal output over an input range of 83 to 147V; Network communications supported via USB port, serial port, SNMP/Web card slot and EPO interface; Current monitoring and switched PDU control via 2 two-outlet load banks; Input: NEMA 5-15P (120V 15A)/Output: 6 NEMA 5-15R (120V). Tripp Lites SMART750RMXL2U intelligent, line interactive rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges. Requires only two rack spaces (2U) in a standard rack enclosure. Large internal batteries offer 34 minutes half load runtime and 16 minutes at full load. Runtime is expandable with optional BP24V28-2U and BP24V70-3U external battery packs. Maintains regulated 120V nominal output without using battery power during brownouts and overvoltages from 83 to 147V. 750VA/450 watt power handling capability supports a variety of networking, telecom and other sensitive electronic applications. Includes a total of 6 outlets arranged in 2 load banks that are individually controllable via software interface to reboot select equipment on demand or automatically shed less significant loads to extend battery runtime for more critical equipment. Supports remote monitoring of UPS and site power conditions via built-in USB and DB9 monitoring ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter. Emergency Power Off (EPO) interface offers option for instantaneous power-off of UPS and connected equipment in the case of fire or emergency. Multi-function audible alarms and set of 5 front panel LEDs offer at-a-glance notification of UPS and line power status. Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise. Find the TrippLite UPS appropriate for your needs. Try the TrippLite UPS Sizing Guide Today. Includes UPS System, PowerAlert software with USB and DB9 cables, Mounting hardware for 4 post rackmount installation, Cable for Emergency Power Off interface, Instruction manual with warranty information. * SMART750RMXL2U line interactive UPS offers voltage regulation and battery support, plus complete AC surge suppression. * Supports 2U rackmount and upright tower applications (2-9USTAND accessory sold separately). * Full time sine wave output offers guaranteed compatibility with all equipment types. * Supports a max load of 750VA for 16 minutes and a half load of 375VA for 34 minutes. * Expandable runtime with BP24V28-2U and BP24V70-3U rack/tower external battery packs. * Maintains regulated 120V nominal output 83 to 147V * 750VA/450 watt power handling capability supports a variety of sensitive electronic loads. * Includes 6 UPS supported outlets arranged in 2 individually controllable load banks. * Built in USB and DB9 serial ports support remote monitoring of UPS and site power conditions. * Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter. * Emergency Power Off (EPO) interface with cable. * Multi-function audible alarms and set of 5 front panel LEDs. * Network-grade AC surge suppression * Attractive all-black color scheme * UPS battery set ships fully assembled and ready for installation, no time consuming connection of internal batteries by user is necessary. * Two year warranty with $250,000 connected equipment insurance (USA & Canada only). * Mounting hardware included for 4 post rackmount enclosures, 2 post telecom rack compatible with separate purchase 2POSTRMKITWM, compatible with upright tower installation with included hardware. -- SPECIFICATIONs ----------------------------------- OUTPUT - Volt amp capacity : 750 VA Watt capacity : 450 Watts Nominal voltage : 120V AC Voltage regulation: LINE MODE: Sine wave line voltage 120V (-21% +8%). BATTERY MODE: Sine wave output within 5% of 120VAC. Frequency regulation: LINE MODE: Passes line frequency of 60Hz +/-10%. BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz. Outlets : (6) NEMA 5-15R output receptacles Load Management : Includes 2 load banks, each with 2 outlets that support automated load shedding and remote reboot on demand of locked network devices. Configurable via PowerAlert software to automatically switch off optional loads, like monitors, to increase available runtime for servers and other critical devices. Overload Protection: Via 15A input circuit breaker INPUT - Maximum amps : 6.8 A Connection type : NEMA 5-15P Cord length : 10 ft. Recommended Service: 15A 120VAC BATTERY - Full load runtime : 16 minutes Half load runtime : 34 minutes Expandable runtime: Runtime is expandable with optional external rack/tower battery packs BP24V28-2U (limit 1) or BP24V70-3U (multi-pack compatible). DC system voltage : 24 VDC Typical lifespan : 4~6 years, depending on usage Recharge rate : 2~4 hours to 90% Connects to UPS : via DC connector Battery Access : Battery access door allows hot swap battery replacement without powering connected equipment off. VOLTAGE REGULATION- Voltage regulation: Line-interactive voltage regulation system corrects input voltages between 83 and 147 back to usable 120V nominal levels. Overvoltage correction: Input voltages between 128 and 147 are reduced by 12%. Brownout correction: Input voltages between 83 and 107 are boosted by 14%. LEDS ALARMS & SWITCHES- Front panel LEDs : 5 front panel LEDs Alarms : 3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Switches : Includes 2 front panel mounted push- button switches for system enable, self-test and alarm cancel functions. SURGE/NOISE SUPPRESSION- AC suppression : 480 joules AC suppression response time: Instantaneous EMI/RFI AC noise suppression: Yes COMMUNICATIONs - Network monitoring port: Includes 2 built-in monitoring ports, 1-USB & 1-DB9. Each supports on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment. Supports reboot of all connected devices at once via software interface. Compatible with Tripp Lites PowerAlert software. Software & cabling: Includes PowerAlert UPS monitoring software for network and standalone operating systems. Ships with complete USB and DB9 cabling. SNMP compatibility: Built-in accessory slot accommodates internal SNMPWEBCARD and other network accessories. WatchDog compatibility: Yes, compatible with Tripp Lites Watchdog system service to restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications. LINE/BATTERY TRANSFER- Transfer time line to battery mode: 2~4 milliseconds Low voltage transfer: 83V (resets to line power as line voltage increases to 87V or higher). High voltage transfer: 147V (resets to line power as line voltage decreases to 143V or lower). EPO PORT - Includes RJ11 EPO (emergency power off) port and cable. TVSS GROUNDING- Includes back panel grounding point with thumbscrew for data line surge suppressors and other network accessories requiring a safe grounding point. COLD START - Yes, inverter can be "cold started" to enable temporary AC output during a power failure. CONSTRUCTION- Steel FORM FACTOR - Supports 2U rackmount installation in 4 post rack enclosures. 2 post rackmount installation supported with optional 2POSTRMKITWM. COOLING - Built-in cooling fan APPROVALS - UL1778 (USA), cUL (Canada), FCC Class B (emissions), NOM (Mexico). DIMENSIONS - 17.5"w x 3.5"h x 14.25"d WT.- 35 lbs. www.tripplite.comPackage Contents:
- SMART750RMXL2U UPS System
- PowerAlert Software with USB
- Serial & EPO Cabling
- 4 Post Installation Kit
- Owner's Manual
Features
Package Contents:
PowerAlert Software
Restriction of Hazardous Substances (RoHS)
Taiwan
- SMART750RMXL2U UPS System
- PowerAlert Software with USB
- Serial & EPO Cabling
- 4 Post Installation Kit
- Owner's Manual
Certifications & Standards:
- UL1778
- cUL
- Class B
- NOM
Software Included:
PowerAlert Software
Environmental Compliance:
Restriction of Hazardous Substances (RoHS)
Country of Origin:
Taiwan
Specs
| Power Description | |
| Load Capacity (Watt) | 600 W |
| Input Voltage | 120 V AC |
| Output Voltage |
|
| Load Capacity (VA) | 750 VA |
| Input Current | 6.80 A |
| Physical Characteristics | |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 35.40 lb |
| Height | 3.5" |
| Width | 17.4" |
| Depth | 13.2" |
| Rack Height | 2U |
| Warranty | |
| Limited Warranty | 2 Year |
| Interfaces/Ports | |
| USB | Yes |
| Battery Information | |
| Backup/Run Time (Full Load) | 8.50 Minute |
| Hot Swappable | Yes |
| Backup/Run Time (Half Load) | 21 Minute |
| Typical Battery Recharge Time | 4.50 Hour |
| General Information | |
| Brand Name | Tripp Lite series |
| Manufacturer Website Address | http://www.eaton.com |
| Marketing Information | 750VA/750W/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your valuable IT equipment or destroy data. The SMART750RMXL2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48VRM2U, sold separately). Optional LX Platform Network Management Card Allows Remote Access 24/7 The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules provide a variety of environmental monitoring and control options. NEMA 5-15R Outlets Protect Your Connected Components Eight 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating. Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART750RMXL2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure. Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The two-line front-panel LCD monitoring screen features ten selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations. More from the Manufacturer |
| Product Type | Line-interactive UPS |
| Product Name | SMART750RMXL2U UPS System |
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | SMART750RMXL2U |
| Product Model | SMART750RMXL2U |
| Product Line | SmartPro |
| Technical Information | |
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail | 6 x NEMA 5-15R |
| Plug/Connector Type | NEMA 5-15P |
| Emergency Power OFF | Yes |
| Transfer Time | 4 ms |
| Management | |
| Network Management | SNMP Manageable |
Warranty Information
All Items are Brand New, Factory Sealed and come with a standard warranty. [Read our policies]
View AllClose
Tripp Lite UPS Smart 750VA 450W Rackmount AVR 120V Pure Sign Wave USB DB9 SNMP 2URM (SMART750RMXL2U)
$764.86